Fire Door Collection - Flipbook - Page 5
01482 790790 | info@hurstdoors.co.uk
Not only does the Neuma fds FD30s GRP composite
fire door system demonstrate integrity against fire,
but it has proven performance relative to smoke
control, security, weather, sound insulation and
thermal performance.
Compliance
Weather Testing
Proven to keep fire at bay for more than
30 minutes, the system has been tested
in accordance to BS EN 1634-1:2014+A1:2018
for fire resistance.
The fds system with long nose threshold has been
successfully tested to the BS6375 standard for weather
performance. This means the door has been proven to
consistently deliver against both water and air leakage.
Smoke Control
Sound Insulation
All of our fire doors have successfully achieved
EN1634-3:2004 for resistance to the passage of
smoke, satisfying the requirements of Approved
Document B of building regulations.
The door blank has been tested and proven to
reduce noise by 33db, this is above the minimum
standard required by Approved Document E
of building regulations.
Security
Thermal Performance
Enhanced Security (PAS24:2022) and Secured
by Design (SBD) accredited – meeting the
SBD Police Preferred Specification security
requirements.
Thermal performance (Approved Document L) –
Overall doorset performance is 1.6w/m2K
unglazed and 1.8w/m2K glazed.
Registered Number 3034235
5