Fire Door Collection - Flipbook - Page 19
01482 790790 | info@hurstdoors.co.uk
NEUMA FDS
TEST RESULTS
BS6375 & PAS24
Summary of Results: PAS24:2016
Door style
Glazing
Type
Unit size
Door size
Opening
Test date
Report number
Twin Vertical
Large
1003 x 2077
914 x 2013
In
29/07/19
R20 742 Rev1
Composite Four
Test description
Result
A.3 – Security hardware & manual cylinder test
Pass
B.4.6 – Manual check test
Pass
B.4.4.3 – Infill – mechanical test
Pass
B.4.3 Manipulation test (a)
Pass
B.4.4.4 – Manual cutting test
Pass
B.4.5 Mechanical loading test
Pass
B.4.4.2 – Infill – manual test
Pass
B.4.8 – Soft body impact test
Pass
B.4.9 – Hard body impact test
Pass
Overall Classification in accordance with PAS24:2016
D
Summary of Results: BS6375-1
Door style
Composite Four
Glazing
Type
Unit size
Door size
Opening
Test date
Report number
Twin Vertical
Large
1003 x 2077
914 x 2013
In
29/07/19
R20 739 Rev1
Test method & classification standard
Achieved max. Test pressure
Classification
Air permeability
BS EN 1026:2016 BS EN 12207:2016
600Pa
4
Water tightness
BS EN 1027:2016
BS EN 12208:2000
150Pa
4A
Wind resistance
BS EN 12211:2016
BS EN 12210:2016
800Pa
C2
Classification according to Table 1 of BS 6375-1:2015+A1:2016
800X
19