Neuma fds fire door system
NEUMA FDS
SMOKE TEST
RESULT
EN1634-3:2004
Fanlight Fire Door Unit
Door Style
Taped
Unit Size
Door Size
Test Date
Report
Number
Pressure
Positive
Pressure
Threshold
Taped
1003 x 2557
914 x 2013
28/06/2019
WYC415952/01/a
Negative
Pressure
To meet the
requirements for an
ambient smoke control
doorset (FD30S), the
tested doorset must not
exceed an air leakage
rate of 3.0m3/hr/m @
25Pa pressure
Composite
Four
+
Short Nosed
Cill Cover
Positive
Pressure
Threshold
Un-taped
1003 x 2557
914 x 2013
28/06/2019
WYC415952/01/b
Negative
Pressure
Positive
Pressure
Threshold
Taped
1003 x 2557
914 x 2013
28/06/2019
WYC415952/02/a
Negative
Pressure
Composite
Half Moon
+
Short Nosed
Cill Cover
Positive
Pressure
Threshold
Un-taped
1003 x 2557
914 x 2013
28/06/2019
WYC415952/02/b
Negative
Pressure
Positive
Pressure
Threshold
Taped
1003 x 2557
914 x 2013
28/06/2019
WYC415952/03/a
Negative
Pressure
Composite
Half Moon
+
Short Nosed
Cill Cover
+
Brush Pile
Removed
18
Positive
Pressure
Threshold
Un-taped
1003 x 2557
914 x 2013
28/06/2019
WYC415952/03/b
Negative
Pressure
Pa
Leakage
(m3/hr)
Test Result
(m3/hr/m)
50
7.96
1.60
25
5.06
1.02
10
2.94
0.59
50
7.88
1.59
25
5.45
1.10
10
2.84
0.57
50
8.18
1.39
25
5.37
0.91
10
3.13
0.53
50
8.26
1.40
25
5.75
0.98
10
3.06
0.52
50
11.60
2.34
25
7.76
1.56
10
4.29
0.86
50
11.48
2.31
25
8.23
1.66
10
4.42
0.89
50
11.82
2.01
25
7.86
1.33
10
4.32
0.73
50
11.66
1.98
25
8.32
1.41
10
4.61
0.78
50
11.95
2.41
25
7.93
1.60
10
4.60
0.93
50
12.22
2.46
25
9.17
1.85
10
4.93
0.99
50
12.08
2.05
25
8.25
1.40
10
4.85
0.82
50
12.08
2.08
25
8.25
1.56
10
4.85
0.85